[关键词]
[摘要]
目的:比较白内障微创超声乳化手术前后角膜前表面屈光力(ASF)、角膜真实净屈光力(TNP)和总角膜屈光力(TCRP)分布特点及角膜前后表面曲率半径比(B/F ratio)差异。
方法:前瞻性研究。收集2020-12/2021-05就诊于潍坊眼科医院行2.2mm微切口超声乳化白内障吸除联合人工晶状体植入术的年龄相关性白内障患者156例156眼。术前及术后3mo行Pentacam眼前节生物测量仪检查,收集以角膜顶点和以瞳孔为中心2、4、6mm环上和区域内ASF、TNP和TCRP,以及手术前后B/F ratio。
结果:术后3mo,以角膜顶点为中心2mm直径环上和区域内ASF值较术前均无差异(均P>0.05),而4、6mm直径环上和区域内ASF值较术前均有差异(均P<0.05); 以瞳孔为中心2mm直径环上及区域内ASF值较术前均无差异(均P>0.05)。以角膜顶点为中心和以瞳孔为中心2、4、6mm直径环上和区域内TNP、TCRP值较术前均有差异(均P<0.05)。术前以角膜顶点为中心和瞳孔为中心在2mm与6mm之间环上和4mm与6mm之间环上TCRP值均有差异(均P<0.0167); 在2mm与6mm区域内TCRP值均有差异(均P<0.0167); 术后3mo,以角膜顶点为中心和瞳孔为中心环上TCRP值在2mm与6mm之间、4mm与6mm之间均有差异(均P<0.0167),而以角膜顶点为中心和瞳孔为中心区域内TCRP值仅在2mm与6mm直径范围内有差异(P<0.0167)。B/F ratio术前为81.79%±1.87%,术后3mo为80.68%±2.23%(P<0.001)。
结论:白内障手术前后以角膜顶点和以瞳孔为中心的不同直径环上及区域内各项角膜屈光力参数会有一定的变化和差异,人工晶状体度数计算的K值选择及基于角膜特性的人工晶状体个体化选择时应予以考虑。
[Key word]
[Abstract]
AIM: To compare the distribution characteristics of axial sagittal front power(ASF), true net power(TNP), total corneal refractive power(TCRP)and the difference in back-front corneal radius ratio(B/F ratio)after cataract surgery.
METHODS: A prospective study. A total of 156 patients(156 eyes)with age-related cataract who attend Weifang Eye Hospital for cataract surgery from December 2020 to May 2021 were collected. Pentacam was performed before operation and 3mo after operation to collect ASF, TNP and TCRP on 2, 4 and 6mm diameters rings and areas on the corneal apex and pupil-centered, as well as B/F ratio.
RESULTS: 3mo after operation, there was no statistical difference in ASF on the 2mm diameters ring and area centered on the corneal apex compared with preoperative values(all P>0.05), however, the ASF values on the 4 and 6mm diameters rings and areas were significantly different from those before surgery(all P<0.05); There was no statistical difference in ASF on the 2mm diameters rings and areas centered on the pupil compared with preoperative values(all P>0.05). The postoperative values of TNP and TCRP on the 2, 4 and 6mm diameters rings and areas centered on the corneal apex and centered on the pupil were statistically different before surgery(all P<0.05). Preoperative, TCRP values were different between 2mm and 6mm and between 4mm and 6mm on both corneal apex and pupil-centered rings(all P<0.0167), TCRP values were all different between 2mm and 6mm diameters areas on corneal apex and pupil-centered(all P<0.0167); 3mo after operation, TCRP values were different on corneal apex and pupil-centered rings between 2mm and 6mm and between 4mm and 6mm diameters(all P<0.0167). While TCRP values on the corneal apex and pupil-centered areas were only different between 2mm and 6mm diameters(all P<0.0167). The preoperative B/F ratio of patients was 81.79%±1.87%, and the postoperative B/ F ratio of patients was 80.68%±2.23%(P<0.001).
CONCLUSION: Corneal parameters of different diameters of rings and areas centered on the corneal apex and pupil before and after cataract surgery may change and differ, which should be taken into account when selecting the K value for intraocular lens calculation and individualizing the selection of IOLs based on corneal characteristics.
[中图分类号]
[基金项目]
国家卫生健康委“十三五”规划全国重点课题(No.YYWS1609)